Model
CT-1002-201
Made by Coil Winding Specialist, INC. · Orange, CA
- Material
- UL_recognized_130C_magnet_wire
- Phase shift
- 3.33deg
- Ratio error
- -0.013%
- Bobbin rating
- ClassB_130C
- Dc resistance
- 156_ohms
- Accuracy class
- 0.5%
- Frequency band
- 50-60Hz
- Operating temp
- -25C_to_80C
- Output voltage
- 1.505V
- Burden resistor
- 100_ohms
- Primary current range
- 0.02-60A
- Rated primary current
- 0.02A-30A
- Dielectric withstanding voltage
- 2.5kV_rms
- Product class
- Specialty transformers, including indoor and outdoor instrument transformers, open core and coil transformer units, arc welder transformers, and high-intensity discharge lamp transformers (excluding fluorescent lamp ballasts)NAPCS 2039725000