PerkFilter Vault

Made by Oldcastle Infrastructure, INC. · Atlanta, GA

Size
8'x12'
Rebar
ASTM A615/A706 grade60
Cement
ASTM C150
Material
concrete
Standard
ASTM C890,ASTM C913,ACI 318-14
Strength
5000psi
Cartridge
18"
Standards
ASTM C890
Cartridges
30"
Dimensions
4'x8'
Pipe inlet
Ø30"
Design load
AASHTO HS-20-44
Wall thickness
6"
Aci 318-14,rebar
ASTM A615/A706 G60,cement=ASTM C150,design_load=AASHTO HS-20-44
Concrete strength
5000psi
Aci 318-14,design load
HS-20-44

From Oldcastle Infrastructure, INC.’s own documents · read October 15, 2026 · not verified by FactoryRegistry

3 families in PerkFilter Vault

40 models

ModelSizeCartridgesStandardStrength
3/4" Joint————
4" Divider Wall————
5'-0" Design Soil Cover————
5"x26" Outlet Window5"x26"———
6" Wall Thickness————
6"x18" Inlet Window6"x18"———
18" Cartridge18in———
5000psi Concrete Strength———5000psi
AASHTO HS-20-44 Loading——AASHTO HS-20-44—
AccessCover Ø24"Ø24"———
AccessCover Ø36"Ø36"———
ACI 318-14 Standard——ACI 318-14—
ASTM C890 Standard——ASTM C890—
ASTM C913 Standard——ASTM C913—
DividerWall————
FalseFloorSupportSpacer————
Ø18" Access CoverØ18"———
Ø24" Max Pipe InletØ24"———
Ø24" Max Pipe OutletØ24"———
PFV-48-123 under it—12"——
PFV-48-18————
PFV-48-244'x8'———
PFV-48-304'x8',cartridge=30",concrete_strength=5000psi———
PFV-68-12————
PFV-68-246'x8'24"——
PFV-612-126'x12'12"—5000psi
PFV-612-24————
PFV-612-30————
PFV-812-12————
PFV-812-18—20,concrete_strength=5000psi,design_load=AASHTO HS-20-44,soil_cover=5'-0",water_table=below_precast,earth_pressure=45pcf——
PFV-812-24————
PFV-812-30————
PFV-816-128'x16',cartridges=12",concrete_strength=5000psi———
PFV-816-18————
PFV-816-248'x16',cartridges=24",concrete_strength=5000psi———
PFV-816-308'x16'30"——
PFV-820-12————
PFV-820-18—18" inlet=Ø30" outlet=Ø30" cartridge_quantity=36——
PFV-820-24————
PFV-820-30————

Documents

  • PFV-48-12Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-48-18Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-48-24Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-48-30Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-612-12Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-612-18Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-612-24Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-612-30Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-68-12Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-68-18Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-68-24Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-68-30Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-812-12Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-812-18Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-812-24Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-812-30Specification sheet · 1 page · 0.5 MB · named on page 1
  • PFV-816-12Specification sheet · 1 page · 0.6 MB · named on page 1
  • PFV-816-18Specification sheet · 1 page · 0.6 MB · named on page 1
  • PFV-816-24Specification sheet · 1 page · 0.6 MB · named on page 1
  • PFV-816-30Specification sheet · 1 page · 0.6 MB · named on page 1
  • PFV-820-12Specification sheet · 1 page · 0.6 MB · named on page 1
  • PFV-820-18Specification sheet · 1 page · 0.6 MB · named on page 1
  • PFV-820-24Specification sheet · 1 page · 0.6 MB · named on page 1
  • PFV-820-30Specification sheet · 1 page · 0.6 MB · named on page 1
Where this comes from — 24 documents

A machine read this from documents Oldcastle Infrastructure, INC. publishes on its own website, as of October 15, 2026. FactoryRegistry has not verified it; the documents are the authority.