Model · Carried
Genetron® ST-20 Flush
Carried by United Refrigeration INC · made by Honeywell International, Inc.
Its documents name it and state no specifications.
From United Refrigeration INC’s own documents · read October 12, 2026 · not verified by FactoryRegistry
Safety data
- Signal word
- None on the sheet
- Transport
- UN1950 Aerosols, non-flammable, class 2.2
- Form
- liquid
- Odor
- slight sweet ether-like
- Color
- colourless
- Vapor pressure
- 1,310 hPa
- Partition coefficient
- noctanol/water : log Pow: 1.35
- Boiling point/boiling range
- 15 °C (59 °F)
| Ingredient | CAS number | Share |
|---|---|---|
| Chemical Name CAS-No. Concentration 1,1,1,3,3-Pentafluoropropane | 460-73-1 | 40.00 - 70.00 % |
| 1,1,1,2-Tetrafluoroethane | 811-97-2 | 10.00 - 30.00 % |
| trans-Dichloroethylene | 156-60-5 | 10.00 - 30.00 % |
From the company’s safety data sheet · read October 12, 2026 · the sheet is the authority · open the sheet (PDF)
Documents
Where this comes from — 1 document
A machine read this from documents United Refrigeration INC publishes on its own website, as of October 12, 2026. FactoryRegistry has not verified it; the documents are the authority.
- 00000000000002236255 1381418243418.rtf, page 1: “Genetron® ST-20 Flush”